{"id":1248,"date":"2025-04-30T15:09:43","date_gmt":"2025-04-30T13:09:43","guid":{"rendered":"https:\/\/spgdrycooling.com\/?post_type=reference&#038;p=1248"},"modified":"2025-06-23T10:17:52","modified_gmt":"2025-06-23T08:17:52","slug":"caso-practico-lisahally","status":"publish","type":"reference","link":"https:\/\/spgdrycooling.com\/es\/reference\/case-study-lisahally\/","title":{"rendered":"Caso pr\u00e1ctico: Lisahally"},"content":{"rendered":"<p class=\"has-medium-font-size wp-block-paragraph\">La central el\u00e9ctrica de Lisahally, situada a unos 117 km al noroeste de la ciudad de Belfast, en el norte de Irlanda, es una central de biomasa de 15,8 MWe.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">Condensador refrigerado por aire SPG ModuleAir\u2122, dise\u00f1ado y fabricado para la central el\u00e9ctrica de biomasa renovable de Lisahally (Evermore), situada en el puerto de Londonderry, Irlanda.<\/p>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">La central el\u00e9ctrica generar\u00e1 15,8 MWe de energ\u00eda el\u00e9ctrica, lo que equivale a la energ\u00eda necesaria para abastecer a 25 000 hogares y empresas de la zona.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Necesidades<\/h2>\n\n\n\n<ul class=\"wp-block-list has-medium-font-size\">\n<li>Consiga una baja contrapresi\u00f3n de la turbina para obtener un rendimiento \u00f3ptimo de la misma.<\/li>\n\n\n\n<li>Centrarse en el ajustado calendario de suministro de materiales mediante una colaboraci\u00f3n estrecha e intensa entre los equipos de ingenier\u00eda y de proyectos, con el fin de cumplir con el plan.<\/li>\n\n\n\n<li>Se hace hincapi\u00e9 en el montaje en f\u00e1brica de los principales componentes de ModuleAir\u2122 (haces de tubos, estructura de acero), dimensionados para optimizar el transporte en contenedores y agilizar el proceso de montaje.<\/li>\n<\/ul>\n\n\n\n<div style=\"height:29px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large\"><img fetchpriority=\"high\" decoding=\"async\" width=\"1024\" height=\"683\" data-id=\"1251\" src=\"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-authorized-P1060863-1024x683.jpg\" alt=\"\" class=\"wp-image-1251\" srcset=\"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-authorized-P1060863-1024x683.jpg 1024w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-authorized-P1060863-300x200.jpg 300w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-authorized-P1060863-768x512.jpg 768w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-authorized-P1060863-1536x1024.jpg 1536w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-authorized-P1060863-2048x1365.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"576\" data-id=\"1250\" src=\"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/2015-Lisahally-15MW-Northern-Ireland-1024x576.jpg\" alt=\"\" class=\"wp-image-1250\" srcset=\"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/2015-Lisahally-15MW-Northern-Ireland-1024x576.jpg 1024w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/2015-Lisahally-15MW-Northern-Ireland-300x169.jpg 300w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/2015-Lisahally-15MW-Northern-Ireland-768x432.jpg 768w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/2015-Lisahally-15MW-Northern-Ireland-1536x864.jpg 1536w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/2015-Lisahally-15MW-Northern-Ireland-2048x1152.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"768\" data-id=\"1249\" src=\"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-1024x768.jpg\" alt=\"\" class=\"wp-image-1249\" srcset=\"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-1024x768.jpg 1024w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-300x225.jpg 300w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-768x576.jpg 768w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-1536x1152.jpg 1536w, https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-2048x1536.jpg 2048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Soluci\u00f3n<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">ModuleAir\u2122 es un enfoque innovador para la condensaci\u00f3n de vapor que optimiza el dise\u00f1o y las caracter\u00edsticas de rendimiento de los condensadores refrigerados por aire.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Ejecuci\u00f3n<\/h2>\n\n\n\n<ul class=\"wp-block-list has-medium-font-size\">\n<li>Equipos de alta calidad y alto rendimiento entregados de acuerdo con el calendario de entrega extremadamente exigente del proyecto.<\/li>\n\n\n\n<li>R\u00e1pida finalizaci\u00f3n de la construcci\u00f3n y puesta en marcha temprana de la central el\u00e9ctrica<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Ventajas<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\">Alto rendimiento, baja contrapresi\u00f3n y mejor rendimiento en condiciones de baja temperatura ambiente.<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Ahorro de material de construcci\u00f3n de hasta 251 TP3T en comparaci\u00f3n con el dise\u00f1o cl\u00e1sico en forma de A.<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Se reduce la soldadura in situ de los conductos de vapor: no es necesario soldar in situ el haz ni la placa de tubos.<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Reducci\u00f3n del peso del acero estructural y de los conductos<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Menos haces de intercambiadores de calor<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Menor impacto visual: menor altura y menor superficie ocupada.<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Menor n\u00famero de haces de tubos con aletas.<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Reducci\u00f3n del 50 % en el tiempo de producci\u00f3n de piezas de acero montadas in situ.<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Mejora de la log\u00edstica de entrega.<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Menor tiempo de construcci\u00f3n.<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Menos operaciones de elevaci\u00f3n.<\/li>\n\n\n\n<li class=\"has-medium-font-size\">Una construcci\u00f3n m\u00e1s eficiente y segura.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>","protected":false},"excerpt":{"rendered":"<p>La central el\u00e9ctrica de Lisahally, situada a unos 117 km al noroeste de la ciudad de Belfast, en el norte de Irlanda, es una central de biomasa de 15,8 MWe.<\/p>","protected":false},"featured_media":1249,"template":"","meta":{"_acf_changed":true},"product":[36],"sector":[26],"class_list":["post-1248","reference","type-reference","status-publish","has-post-thumbnail","hentry","product-moduleair","sector-biomass-waste-to-energy"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Case Study: ModuleAir\u2122 at Lisahally Biomass Plant<\/title>\n<meta name=\"description\" content=\"SPG\u2019s ModuleAir\u2122 boosts Lisahally\u2019s 15.8 MWe biomass plant with low back pressure, fast installation, and 25% construction savings.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/spgdrycooling.com\/es\/referencia\/caso-practico-lisahally\/\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Case Study: ModuleAir\u2122 at Lisahally Biomass Plant\" \/>\n<meta property=\"og:description\" content=\"SPG\u2019s ModuleAir\u2122 boosts Lisahally\u2019s 15.8 MWe biomass plant with low back pressure, fast installation, and 25% construction savings.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/spgdrycooling.com\/es\/referencia\/caso-practico-lisahally\/\" \/>\n<meta property=\"og:site_name\" content=\"SPG Dry Cooling\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/spgdrycooling\/\" \/>\n<meta property=\"article:modified_time\" content=\"2025-06-23T08:17:52+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1920\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Tiempo de lectura\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutos\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/reference\\\/case-study-lisahally\\\/\",\"url\":\"https:\\\/\\\/spgdrycooling.com\\\/reference\\\/case-study-lisahally\\\/\",\"name\":\"Case Study: ModuleAir\u2122 at Lisahally Biomass Plant\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/reference\\\/case-study-lisahally\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/reference\\\/case-study-lisahally\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/spgdrycooling.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/lisahally-nov-2014a-scaled.jpg\",\"datePublished\":\"2025-04-30T13:09:43+00:00\",\"dateModified\":\"2025-06-23T08:17:52+00:00\",\"description\":\"SPG\u2019s ModuleAir\u2122 boosts Lisahally\u2019s 15.8 MWe biomass plant with low back pressure, fast installation, and 25% construction savings.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/reference\\\/case-study-lisahally\\\/#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/spgdrycooling.com\\\/reference\\\/case-study-lisahally\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/reference\\\/case-study-lisahally\\\/#primaryimage\",\"url\":\"https:\\\/\\\/spgdrycooling.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/lisahally-nov-2014a-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/spgdrycooling.com\\\/wp-content\\\/uploads\\\/2025\\\/04\\\/lisahally-nov-2014a-scaled.jpg\",\"width\":2560,\"height\":1920},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/reference\\\/case-study-lisahally\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/spgdrycooling.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Case study: Lisahally\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/#website\",\"url\":\"https:\\\/\\\/spgdrycooling.com\\\/\",\"name\":\"SPG Dry Cooling\",\"description\":\"Innovative cooling solutions for the energy sector\",\"publisher\":{\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/spgdrycooling.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"es\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/#organization\",\"name\":\"SPG Dry Cooling\",\"url\":\"https:\\\/\\\/spgdrycooling.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"es\",\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/spgdrycooling.com\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Logos-companies_paharpur_spgdc.png\",\"contentUrl\":\"https:\\\/\\\/spgdrycooling.com\\\/wp-content\\\/uploads\\\/2025\\\/05\\\/Logos-companies_paharpur_spgdc.png\",\"width\":1250,\"height\":521,\"caption\":\"SPG Dry Cooling\"},\"image\":{\"@id\":\"https:\\\/\\\/spgdrycooling.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/spgdrycooling\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/spg-dry-cooling\\\/\",\"http:\\\/\\\/www.youtube.com\\\/channel\\\/UC4eB-kGB2qHe30QWn4DMgrg\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Caso pr\u00e1ctico: ModuleAir\u2122 en la planta de biomasa de Lisahally","description":"El sistema ModuleAir\u2122 de SPG potencia la central de biomasa de 15,8 MWe de Lisahally gracias a su baja contrapresi\u00f3n, su r\u00e1pida instalaci\u00f3n y el ahorro en los costes de construcci\u00f3n del modelo 25%.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/spgdrycooling.com\/es\/referencia\/caso-practico-lisahally\/","og_locale":"es_ES","og_type":"article","og_title":"Case Study: ModuleAir\u2122 at Lisahally Biomass Plant","og_description":"SPG\u2019s ModuleAir\u2122 boosts Lisahally\u2019s 15.8 MWe biomass plant with low back pressure, fast installation, and 25% construction savings.","og_url":"https:\/\/spgdrycooling.com\/es\/referencia\/caso-practico-lisahally\/","og_site_name":"SPG Dry Cooling","article_publisher":"https:\/\/www.facebook.com\/spgdrycooling\/","article_modified_time":"2025-06-23T08:17:52+00:00","og_image":[{"width":2560,"height":1920,"url":"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-scaled.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"Tiempo de lectura":"2 minutos"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/spgdrycooling.com\/reference\/case-study-lisahally\/","url":"https:\/\/spgdrycooling.com\/reference\/case-study-lisahally\/","name":"Caso pr\u00e1ctico: ModuleAir\u2122 en la planta de biomasa de Lisahally","isPartOf":{"@id":"https:\/\/spgdrycooling.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/spgdrycooling.com\/reference\/case-study-lisahally\/#primaryimage"},"image":{"@id":"https:\/\/spgdrycooling.com\/reference\/case-study-lisahally\/#primaryimage"},"thumbnailUrl":"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-scaled.jpg","datePublished":"2025-04-30T13:09:43+00:00","dateModified":"2025-06-23T08:17:52+00:00","description":"El sistema ModuleAir\u2122 de SPG potencia la central de biomasa de 15,8 MWe de Lisahally gracias a su baja contrapresi\u00f3n, su r\u00e1pida instalaci\u00f3n y el ahorro en los costes de construcci\u00f3n del modelo 25%.","breadcrumb":{"@id":"https:\/\/spgdrycooling.com\/reference\/case-study-lisahally\/#breadcrumb"},"inLanguage":"es","potentialAction":[{"@type":"ReadAction","target":["https:\/\/spgdrycooling.com\/reference\/case-study-lisahally\/"]}]},{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/spgdrycooling.com\/reference\/case-study-lisahally\/#primaryimage","url":"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-scaled.jpg","contentUrl":"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/04\/lisahally-nov-2014a-scaled.jpg","width":2560,"height":1920},{"@type":"BreadcrumbList","@id":"https:\/\/spgdrycooling.com\/reference\/case-study-lisahally\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/spgdrycooling.com\/"},{"@type":"ListItem","position":2,"name":"Case study: Lisahally"}]},{"@type":"WebSite","@id":"https:\/\/spgdrycooling.com\/#website","url":"https:\/\/spgdrycooling.com\/","name":"Refrigeraci\u00f3n por aire de SPG","description":"Soluciones innovadoras de refrigeraci\u00f3n para el sector energ\u00e9tico","publisher":{"@id":"https:\/\/spgdrycooling.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/spgdrycooling.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"es"},{"@type":"Organization","@id":"https:\/\/spgdrycooling.com\/#organization","name":"Refrigeraci\u00f3n por aire de SPG","url":"https:\/\/spgdrycooling.com\/","logo":{"@type":"ImageObject","inLanguage":"es","@id":"https:\/\/spgdrycooling.com\/#\/schema\/logo\/image\/","url":"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/05\/Logos-companies_paharpur_spgdc.png","contentUrl":"https:\/\/spgdrycooling.com\/wp-content\/uploads\/2025\/05\/Logos-companies_paharpur_spgdc.png","width":1250,"height":521,"caption":"SPG Dry Cooling"},"image":{"@id":"https:\/\/spgdrycooling.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/spgdrycooling\/","https:\/\/www.linkedin.com\/company\/spg-dry-cooling\/","http:\/\/www.youtube.com\/channel\/UC4eB-kGB2qHe30QWn4DMgrg"]}]}},"_links":{"self":[{"href":"https:\/\/spgdrycooling.com\/es\/wp-json\/wp\/v2\/reference\/1248","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/spgdrycooling.com\/es\/wp-json\/wp\/v2\/reference"}],"about":[{"href":"https:\/\/spgdrycooling.com\/es\/wp-json\/wp\/v2\/types\/reference"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/spgdrycooling.com\/es\/wp-json\/wp\/v2\/media\/1249"}],"wp:attachment":[{"href":"https:\/\/spgdrycooling.com\/es\/wp-json\/wp\/v2\/media?parent=1248"}],"wp:term":[{"taxonomy":"product","embeddable":true,"href":"https:\/\/spgdrycooling.com\/es\/wp-json\/wp\/v2\/product?post=1248"},{"taxonomy":"sector","embeddable":true,"href":"https:\/\/spgdrycooling.com\/es\/wp-json\/wp\/v2\/sector?post=1248"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}